With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements.
The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.
Features
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.
Large white LED backlight to work in poorly lit areas
Resistance and continuity
Frequency and capacitance
Maximum Voltage ac/dc 600V10A ac/dc current measurement (20 A overload for 30-seconds max)
Min/Max/Average to record signal fluctuations
CAT III 600 V safety rated
Safety conformance
All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA,
TÜV listed and VDE.
Specifications
Maximum voltage between any terminal and earth ground: 600 V
Surge protection: 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display: Digital: 6,000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating Temperature: -10 °C to + 50 °C
Storage Temperature: -40 °C to + 60 °C
Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life
400 hours typical, without backlight
Accuracy Specifications
DC millivolts
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.00 V / 0.1 V
Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 true-rms
Range: 600.0 mV
Resolution: 0.1 mV
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms
Range/Resolution: 6.000 V / 0.001 V
Range/Resolution: 60.00 V / 0.01 V
Range/Resolution: 600.0 V / 0.1 V
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
Continuity
Range: 600 Ω
Resolution: 1 Ω
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω
Range/Resolution: 6.000 kΩ / 0.001 kΩ
Range/Resolution: 60.00 kΩ / 0.01 kΩ
Range/Resolution: 600.0 kΩ / 0.1 kΩ
Range/Resolution: 6.000 MΩ / 0.001 MΩ
Accuracy: 0.9 % + 1
Range/Resolution: 40.00 MΩ / 0.01 MΩ
Accuracy: 5 % + 2
Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%
Lo-Z Capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30-seconds max
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30-seconds max
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications
- Size. 167 x 84 x 46 mm (6.57″ x 3.31″ x 1.82″)
- Weight 550 g
- Warranty:3 years